Dec 25,2024
Power quality analysis and improvement measures for cement plants The size of system voltage deviation, the degree of three-phase voltage imbalance, and the reliability of power supply have an important impact on the safe operation and service life of electrical equipment, and are also directly related to the safety, stability and economic operation of the cement plant power system itself. 1. Powe...
read more
-
Feb 06,2025
Photovoltaic inverter harmonic control is an important technical issue in photovoltaic power generation systems, which is related to the stability of photovoltaic inverter operation and power generation efficiency. In photovoltaic power generation systems, inverters are one of the nonlinear electrical devices because their voltage-current characteristics do not conform to a linear relationship. Th...
read more
-
Feb 19,2025
In modern power systems, low-voltage capacitor cabinets, as an important reactive power compensation device, play an indispensable role. It can effectively improve the power factor of the power system, reduce line losses, improve the quality of power, and ensure the stable operation of the power system. Ⅰ. Working principle The low-voltage capacitor cabinet mainly realizes reactive power compensat...
read more
-
Mar 01,2025
I. Industry driving factors 1. Demand for new energy power generation and grid upgrades The volatility and intermittency of new energy power generation (such as wind power and photovoltaic power generation) put forward higher requirements for grid stability, and it is necessary to rely on power quality equipment (such as reactive power compensation and harmonic control) to achieve grid stability....
read more
-
Mar 14,2025
SVG low-voltage static reactive generator is mainly composed of control part, power part and starting part. The following is its detailed internal structure and working principle: Internal structure 1. Control part: mainly composed of computer, control board, sampling board, drive board, etc. The sampling board collects the voltage, current and other parameters of the power grid in real time. The ...
read more
-
Mar 25,2025
Low-voltage static VAR generator (SVG) and low-voltage capacitor cabinet are both devices used for reactive power compensation, but there are many differences in working principle, performance characteristics, application scenarios, etc., as follows: Working principle Low-voltage SVG: Based on power electronics technology, by controlling power devices such as IGBT, the DC side electric energy is c...
read more
-
Apr 24,2025
Analysis of the situation where the system load exceeds the transformer capacity configuration when the transformer and photovoltaic are used at the same time. Phenomenon and cause 1. Power fluctuation superposition: The power generation power of the photovoltaic system is affected by factors such as light intensity and weather conditions, and fluctuates significantly. When there is sufficient sun...
read more
-
May 08,2025
1. Overview of the development of the power quality optimization and management equipment industry Power quality refers to the nature and characteristics of the power provided to users by the power supply system, including voltage fluctuations, frequency stability, harmonic content, voltage flicker, power interruption and other aspects. Good power quality is the basis for ensuring the normal opera...
read more
-
May 22,2025
The low power factor of a single-phase circuit will lead to a decrease in equipment efficiency and an increase in line loss. To control the power factor, we need to analyze the causes and take targeted measures. The following are common control methods: I. Common causes of low power factor 1. Mainly inductive loads Equipment such as fluorescent lamps, motors, transformers, etc., need to consume re...
read more
-
May 26,2025
Both capacitor banks and filter banks are used in low voltage (LV) power systems for reactive power compensation and power quality improvement, but they serve different primary purposes. 1. Low Voltage Capacitor Banks Purpose: Reactive power compensation (power factor correction) Voltage support (reduces line losses and improves efficiency) Components: Capacitors (fixed or switched) Contactors/thy...
read more
-
Jun 19,2025
In low-voltage power distribution systems (usually 400V and below), the hybrid solution of static VAR generator (SVG) and traditional capacitor compensation is a compromise between performance and cost. The following is an in-depth analysis of the advantages and disadvantages of hybrid compensation and the risk of component damage based on technical principles and application scenarios: Ⅰ. Technic...
read more
-
Aug 19,2025
In the marine industry, active filters are primarily used to address harmonics, improve power quality, and ensure stable operation of shipboard power systems. Specific applications are as follows: 1. Suppressing Harmonics in Radar Systems: Shipborne radar equipment has large capacity and experiences significant load fluctuations during operation, generating significant harmonics. Total harmonic di...
read more
-
Aug 19,2025
When multiple modules of an active power filter are operated in parallel, slow response and reduced filtering effectiveness are often related to imbalances in core aspects such as inter-module coordinated control, signal synchronization, and current distribution. The specific causes can be analyzed from the following aspects: Ⅰ. Insufficient inter-module synchronization accuracy Multiple modules i...
read more
-
Oct 21,2025
Established in 2001 and headquartered in Bengbu City, Anhui Province, ZDDQ(ANHUI ZHONGDIAN ELECTRIC CO.,LTD) is a leading integrated enterprise specializing in power quality and distribution solutions. Our modern manufacturing facility spans 25,000 square meters and employs nearly 200 professionals, with a specialized R&D team accounting for one-quarter of our workforce. Production & Capab...
read more
-
Dec 18,2025
For years, capacitor banks have been the standard solution for power factor correction. Yet, their slow, fixed-step operation struggles with today's dynamic industrial loads, often causing over-correction or harmful resonance. The Static Var Generator (SVG) represents a fundamental upgrade. It's a fully electronic system that delivers precise, instantaneous reactive power compensation. Think of it...
read more
-
Apr 01,2026
Product Uses: Intelligent reactive power compensation capacitor banks are "energy-saving experts" in power systems. Their main functions are: Compensating for reactive power losses in the power grid, improving the power factor, and avoiding power factor penalties for the power sector; (B) Reducing line losses and improving the power supply efficiency of the power grid; Stabilizing the power grid v...