Feb 04,2020
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Mar 26,2021
Congratulations to the company for mentioning the new car Anhui Zhongdian Electric Co., Ltd., founded in 1988, is affiliated to the Design and Research Institute of the Ministry of Machinery Industry. It is a high-tech professional engaged in the R&D, production, sales and service of power quality equipment technology companies. The company passed the ISO9000 quality system certification in 20...
read more
-
Jun 16,2021
Power factor penalty in power bills We've found that many people struggle to understand how Power Factor (PF) impacts demand charges. Frequently, end use customers pay a significant premium each month in demand charges because their PF is below a threshold set by the utility in the rate tariff. Oftentimes its not obvious to the untrained eye when there are extra charges associated with a bad PF on...
read more
-
Jun 10,2022
Harmonic Mitigation Expert---Active Power Filter The main hazards of harmonics: Increase the load of power facilities, reduce the power factor of the system, reduce the effective capacity and efficiency of power generation, transmission and power consumption equipment, resulting in equipment waste, line waste and power loss; Causes the resonance of reactive power compensation capacitors and the am...
read more
-
Aug 22,2022
The application of distribution system capacitor banks has long been accepted as a necessary step in the design of distribution feeders. Design considerations often include traditional factors such as voltage support, power factor, and released capacity. However, as customer systems evolve through the use of power electronics, the distribution system design of the future will include power quality...
read more
-
Feb 19,2024
What is harmonics issues in AC and DC grid? In AC and DC grids, harmonics refer to the presence of frequency components that are integer multiples of the fundamental frequency. Harmonics can be problematic because they can cause various issues such as: Voltage and Current Distortion: Harmonics in the grid can distort the shape of the voltage and current waveforms, resulting in distorted sine waves...
read more
-
Sep 05,2024
Application of reactive power compensation device SVG: Power system: SVG can be used for reactive power compensation and voltage regulation of power system to improve the stability and reliability of power grid. It can help power system reduce power loss, improve voltage quality, and improve power factor and efficiency of power grid. Industrial field: SVG can be used for reactive power compensatio...
read more
-
Sep 10,2025
1. Electrical Resonance What is Resonance? In an AC circuit, electrical resonance is a condition where the inductive reactance (X_C) become equal, canceling each other out. This leaves only the circuit resistance (X_L = 2πfL): Opposition from inductors (e.g., motors, transformers). Increases with frequency. Capacitive Reactance (f_r) This is the specific frequency where f_r = 1 / (2π√(LC)) Wh...
read more
-
Apr 13,2026
First, remember this easy-to-remember mnemonic for on-site recall: 1. Ask about the symptoms; 2. Inspect the appearance; 3. Disconnect the fault in sections; 4. Measure parameters; 5. Test run to prevent recurrence. Step 1: Ask (Understand the Fault Symptoms) First, ask the operator to clarify the situation before starting any work: When did it break down? How did it break down? Were there any unu...
read more