33kv statcom

Medium voltage Automatic Capacitor banks with harmonic filters

Medium voltage automatic power factor correction/reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.

  • Brand:

    ZDDQ
  • item no.:

    ZD-GWJ-M/6-C
  • Payment:

    LC,TT
  • product origin:

    China
  • Color:

    RAL7032
  • shipping port:

    Shanghai
  • Lead Time:

    15days
  • Product Detail

Overview of MV Capacitor Banks with filters

Medium voltage Automatic Capacitor banks with harmonic filters aims to improve power factor and enhance power quality, utilising capacitors to offset usually inductive loads(motors).APFC system  increase the efficiency of power supply, delivering immediate cost savings on electricity.

ZD-GWJ Series medium voltage automatic capacitor banks can detect the reactive power needed by the system in real time,compare it with the set value, carry on the automatic intelligent capacitor-switching on/off, make the reactive power of the system achieve dynamic balance, in order to improve the power factor of the system, stabilize the system voltage. 


MV/HV automatic capacitor banks

Power capacitors and reactors


Technical specifications of MV Capacitor banks

Name

Medium voltage Automatic capacitor banks

Model                                          

ZD-GWJ-H/6-                                                                          

Rated Voltage 6Kv~35Kv      
Connection Type     Three phase There wire
Rated Frequency
50/60HZ
Step Capacity 100~1200kVAr
Rated Capacity/panel
2400kVAr
Power Factor 
>0.9
Switch
Vacuum Contactors
Capacitance Tolerance
-5%, +10%
Reactance ratio
6% 12% or customerized
Switching
Automatic switching Capacitors
Storage temperature
-40~85 °C
Working temperature
-25~55 °C
Humidity
≤95%,non-condensate
Dimension (mm)
1200*1600*2400
Installation
Indoor, free standing
Altitude 
 <1500m without de-rating
Certification
ISO9001,CCC, Type Test Report


Benefits of MV Capacitor banks

  • Save money on electricity costs

The Electricity Authorities, force companies distributing electricity to apply financial penalties to utilities that have a substantial contractual power and low energy cosφ (generally 0,9). ZDDQ capacitor banks allow you to avoid penalties, which often are not reflected in the bill, and then are paid by the final user without even realizing it.Meanwhile,capacitor banks is widely convenient, both in the case of central and individual compensation, with Pay-Back less than or equal to 1 year.

  • Reduce investment costs

ZDDQ APFC Capacitor banks makes it possible to start out with a smaller system and, if necessary, expand the system by adding further modules later on.

  • Improve Power Quality

In many industrial electric plants supplied by MT there is a tension considerably distorted, due often to excessive load of MV/LV transformer. ZDDQ APFC Capacitor banks with a consequent load reduction by the transformer allow to bring it back to the operating conditions within the linearity limits, substantially reducing the voltage distortion. Furthermore the proper Power Factor reduces the presence of harmonic currents, and reduce heat, resulting in greater longevity and lower maintenance costs.

  • Maximizing equipment utilization

ZDDQ APFC Capacitor banks reduces the burden on transformers by providing the required reactive power locally, so that more consumers can be supplied by the same transformer.


Application fields of MV Capacitor banks

ZDDQ automatic capacitor banks are widely used for fluctuating loads such as motors, variable frequency drives, melting furnace from Steel Rolling mills,Chemical industry,Cement plant, Suger plant, Textile, Hospitals, Hotels, Building segment,Automobile industry,Oil and gas industry,public grid etc.









Send a Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
related products
automatic Power Factor Correction

6kv APFC panel with individual compensation

6KV APFC panel (automatic power factor correction)/ individual reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
35KV automatic Power Factor Correction

35KV Automatic Power Factor Correction Panel with group compensation

35KV APFC panel (automatic power factor correction)/group reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Automatic Power Factor Correction

27.5KV Active Power Factor Correction Panel based on Static Var Compensator

27.5KV automatic power factor correction/reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Static Var compensator SVC

Medium voltage Static Var Compensator SVC with Vaccum Contactors multi steps switching

Medium voltage Static Var Compensator(SVC) reactive power compensation systems/ automatic power factor correction panels are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Local reactive power compensation

3.3KV Local reactive power compensation for motors,Arc Furnace

3.3KV local reactive power compensation systems( APFC automatic power factor correction) are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Metal Enclosed Harmonic Filter Capacitor Banks

Medium Voltage Metal Enclosed Harmonic Filter Capacitor Banks

Medium Voltage Metal Enclosed Harmonic Filter Banks are custom designed for application on industrial, commercial, and utility power systems that require medium voltage power factor correction, var and voltage support, and mitigation from harmonic resonance or harmonic distortion. The harmonic filter banks are configurable as fixed or automatic controlled with 1 or more stages at voltages from 2.4kV through 38kV.
HV Automatic Capacitor banks

High voltage Automatic Capacitor banks

High votage automatic capacitor banks/reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Automatic Power Factor Control Panel

High voltage Automatic Power Factor Control Panel for Motors VFDs

High voltage automatic power factor control/reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Send a Message
welcome to zddq
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact