Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...
read more
-
Nov 04,2024
Inverters are a type of power electronic device widely used in industrial automation. They adjust the speed of motors by changing the frequency and amplitude of the motor input voltage. Although inverters improve energy efficiency and control performance, they generate harmonics during operation, which have an adverse effect on power grids and equipment. Understanding the causes and principles of ...
read more
-
Dec 17,2024
With the continuous advancement of science and technology, medical technology has been significantly improved, and advanced medical equipment continues to emerge, greatly improving the quality of medical services. However, the use of nonlinear devices in hospital power distribution systems may produce harmonic currents that can interfere with the normal operation of the system. The accumulation of...
read more
-
Feb 06,2025
Photovoltaic inverter harmonic control is an important technical issue in photovoltaic power generation systems, which is related to the stability of photovoltaic inverter operation and power generation efficiency. In photovoltaic power generation systems, inverters are one of the nonlinear electrical devices because their voltage-current characteristics do not conform to a linear relationship. Th...
read more
-
Mar 01,2025
I. Industry driving factors 1. Demand for new energy power generation and grid upgrades The volatility and intermittency of new energy power generation (such as wind power and photovoltaic power generation) put forward higher requirements for grid stability, and it is necessary to rely on power quality equipment (such as reactive power compensation and harmonic control) to achieve grid stability....
read more
-
Mar 05,2025
Benefits of harmonic control Improve power quality: Harmonics can distort voltage and current waveforms. Controlling harmonics can make voltage and current waveforms closer to sine waves, provide stable and high-quality power for various electrical equipment, ensure normal operation of equipment, and reduce equipment failures and malfunctions caused by power quality problems. Reduce equipment loss...
read more
-
Mar 25,2025
Low-voltage static VAR generator (SVG) and low-voltage capacitor cabinet are both devices used for reactive power compensation, but there are many differences in working principle, performance characteristics, application scenarios, etc., as follows: Working principle Low-voltage SVG: Based on power electronics technology, by controlling power devices such as IGBT, the DC side electric energy is c...
read more
-
May 08,2025
1. Overview of the development of the power quality optimization and management equipment industry Power quality refers to the nature and characteristics of the power provided to users by the power supply system, including voltage fluctuations, frequency stability, harmonic content, voltage flicker, power interruption and other aspects. Good power quality is the basis for ensuring the normal opera...
read more
-
May 26,2025
STATCOM (Static Synchronous Compensator) can help control harmonics, but its primary function is not harmonic filtering. Here's how it relates to harmonics: 1. Primary Role of STATCOM: Reactive Power Compensation: STATCOM provides fast and dynamic reactive power support to regulate voltage and improve power system stability. Voltage Stability: It helps maintain grid voltage by injecting or absorbi...
read more
-
Aug 19,2025
In the marine industry, active filters are primarily used to address harmonics, improve power quality, and ensure stable operation of shipboard power systems. Specific applications are as follows: 1. Suppressing Harmonics in Radar Systems: Shipborne radar equipment has large capacity and experiences significant load fluctuations during operation, generating significant harmonics. Total harmonic di...
read more
-
Aug 19,2025
When multiple modules of an active power filter are operated in parallel, slow response and reduced filtering effectiveness are often related to imbalances in core aspects such as inter-module coordinated control, signal synchronization, and current distribution. The specific causes can be analyzed from the following aspects: Ⅰ. Insufficient inter-module synchronization accuracy Multiple modules i...
read more
-
Sep 10,2025
1. Electrical Resonance What is Resonance? In an AC circuit, electrical resonance is a condition where the inductive reactance (X_C) become equal, canceling each other out. This leaves only the circuit resistance (X_L = 2πfL): Opposition from inductors (e.g., motors, transformers). Increases with frequency. Capacitive Reactance (f_r) This is the specific frequency where f_r = 1 / (2π√(LC)) Wh...
read more
-
Oct 21,2025
Established in 2001 and headquartered in Bengbu City, Anhui Province, ZDDQ(ANHUI ZHONGDIAN ELECTRIC CO.,LTD) is a leading integrated enterprise specializing in power quality and distribution solutions. Our modern manufacturing facility spans 25,000 square meters and employs nearly 200 professionals, with a specialized R&D team accounting for one-quarter of our workforce. Production & Capab...
read more
-
Oct 30,2025
Active Harmonic Filter is a high-power, fast-switching electronic amplifier. Its job is to continuously monitor the electrical system and instantly inject equal but opposite "anti-harmonic" currents to cancel out the distortions. This demanding process generates a significant amount of waste heat, and managing this heat is paramount for several key reasons: 1. To Protect the Power Semiconductors (...
read more
-
Dec 10,2025
The Variable Frequency Drive (VFD) is a powerhouse of modern industry, enabling precise motor control and dramatic energy savings. Yet, this efficiency comes with a hidden electrical toll: harmonic distortion. The Active Harmonic Filter (AHF) is the critical solution that neutralizes this threat, ensuring system reliability and clean power. The Harmonic Challenge from VFDs A VFD's operation—conver...
read more
-
Apr 13,2026
First, remember this easy-to-remember mnemonic for on-site recall: 1. Ask about the symptoms; 2. Inspect the appearance; 3. Disconnect the fault in sections; 4. Measure parameters; 5. Test run to prevent recurrence. Step 1: Ask (Understand the Fault Symptoms) First, ask the operator to clarify the situation before starting any work: When did it break down? How did it break down? Were there any unu...
read more
-
Apr 17,2026
Low Voltage APF Active Power Filter APF Active Power Filter APF stands for Active Power Filter.Also known as Active Harmonic Filter.What is filtering?To put it simply: tap water in rivers contains all kinds of pollutants, and we install a water purifier at home to filter out impurities. Similarly, the current in the power grid is just like river water. APF filters out interference (impurities) in ...
read more
-
Apr 20,2026
Many novice electricians make mistakes when connecting frequency converters, sometimes resulting in inverter errors or even module failure, smoke, and fire. The problem isn't the wiring itself, but rather a lack of understanding of the core principles, especially the common mistake of reversing the input and output wires! This article breaks down the practical wiring methods for frequency converte...
read more