-
Dec 06,2024
Low-voltage SVG (Static Var Generator): A key compensation device for power systems In modern power systems, power quality is a crucial aspect. With the development of industry and the increase of various complex power loads, the balance of reactive power in the power grid has become increasingly critical. As an advanced reactive compensation device, low-voltage SVG (static var generator) plays an...
read more
-
Feb 19,2025
In modern power systems, low-voltage capacitor cabinets, as an important reactive power compensation device, play an indispensable role. It can effectively improve the power factor of the power system, reduce line losses, improve the quality of power, and ensure the stable operation of the power system. Ⅰ. Working principle The low-voltage capacitor cabinet mainly realizes reactive power compensat...
read more
-
Mar 01,2025
I. Industry driving factors 1. Demand for new energy power generation and grid upgrades The volatility and intermittency of new energy power generation (such as wind power and photovoltaic power generation) put forward higher requirements for grid stability, and it is necessary to rely on power quality equipment (such as reactive power compensation and harmonic control) to achieve grid stability....
read more
-
Mar 14,2025
SVG low-voltage static reactive generator is mainly composed of control part, power part and starting part. The following is its detailed internal structure and working principle: Internal structure 1. Control part: mainly composed of computer, control board, sampling board, drive board, etc. The sampling board collects the voltage, current and other parameters of the power grid in real time. The ...
read more
-
Mar 25,2025
Low-voltage static VAR generator (SVG) and low-voltage capacitor cabinet are both devices used for reactive power compensation, but there are many differences in working principle, performance characteristics, application scenarios, etc., as follows: Working principle Low-voltage SVG: Based on power electronics technology, by controlling power devices such as IGBT, the DC side electric energy is c...
read more
-
Apr 24,2025
Analysis of the situation where the system load exceeds the transformer capacity configuration when the transformer and photovoltaic are used at the same time. Phenomenon and cause 1. Power fluctuation superposition: The power generation power of the photovoltaic system is affected by factors such as light intensity and weather conditions, and fluctuates significantly. When there is sufficient sun...
read more
-
May 26,2025
STATCOM (Static Synchronous Compensator) can help control harmonics, but its primary function is not harmonic filtering. Here's how it relates to harmonics: 1. Primary Role of STATCOM: Reactive Power Compensation: STATCOM provides fast and dynamic reactive power support to regulate voltage and improve power system stability. Voltage Stability: It helps maintain grid voltage by injecting or absorbi...
read more
-
Jun 19,2025
The application prospects of static VAR generators (SVG) in China's energy storage industry show significant growth potential, a trend driven by policy support, technological innovation and market demand. The following is an in-depth analysis based on the latest industry dynamics and technological progress: I. Strong support from policies and industry standards National policies clearly list SVG a...
read more
-
Jun 19,2025
In low-voltage power distribution systems (usually 400V and below), the hybrid solution of static VAR generator (SVG) and traditional capacitor compensation is a compromise between performance and cost. The following is an in-depth analysis of the advantages and disadvantages of hybrid compensation and the risk of component damage based on technical principles and application scenarios: Ⅰ. Technic...
read more
-
Oct 21,2025
Established in 2001 and headquartered in Bengbu City, Anhui Province, ZDDQ(ANHUI ZHONGDIAN ELECTRIC CO.,LTD) is a leading integrated enterprise specializing in power quality and distribution solutions. Our modern manufacturing facility spans 25,000 square meters and employs nearly 200 professionals, with a specialized R&D team accounting for one-quarter of our workforce. Production & Capab...
read more
-
Dec 18,2025
For years, capacitor banks have been the standard solution for power factor correction. Yet, their slow, fixed-step operation struggles with today's dynamic industrial loads, often causing over-correction or harmful resonance. The Static Var Generator (SVG) represents a fundamental upgrade. It's a fully electronic system that delivers precise, instantaneous reactive power compensation. Think of it...
read more
-
Feb 07,2026
Below is a partial list of our shipments over the past two weeks at the end of the year: 1. Africa High Voltage Outdoor Water Cooling Statcom FAT and Delivery 2. Eastern European Static Var Generator and Active Harmonic Filter 3. Southeast Asia LV APFC 4. Latin American MV APFC(13.8kV)
read more
-
Apr 01,2026
Product Uses: Intelligent reactive power compensation capacitor banks are "energy-saving experts" in power systems. Their main functions are: Compensating for reactive power losses in the power grid, improving the power factor, and avoiding power factor penalties for the power sector; (B) Reducing line losses and improving the power supply efficiency of the power grid; Stabilizing the power grid v...
read more
-
Apr 16,2026
Low-Voltage Static Var Generator Reactive Power Compensation Device Description Application Scenarios for SVG Reactive Power Compensation Devices Reactive power compensation devices should be installed wherever low-voltage transformers or large-scale electrical equipment are present; their installation is particularly mandatory in industrial facilities, commercial enterprises, and residential area...
read more
-
Apr 24,2026
Reactive Power Compensation Solution for Chemical Plants 1. Problem Background and Requirements Chemical plants typically operate numerous inductive loads, such as large motors (pumps, compressors, fans), transformers, variable frequency drives, and electric arc furnaces. During operation, these devices consume significant amounts of reactive power (Q), leading to the following issues: Low power f...
read more
-
Apr 30,2026
Is there a hidden trick in the electricity bill? The secret path to saving 30% on losses by improving the power factor from 0.7 to 0.95. I.The Impact, Benefits, and Improvement Principles of Power Factor: A building materials factory incurred an annual electricity cost overrun of 500,000 yuan due to a power factor of only 0.7—this is not an isolated case! During power supply, the user's power fact...
read more
-
May 08,2026
1.What is Harmonics? In power systems, the fundamental cause of harmonics is the presence of non-linear loads. When current flows through a load and does not maintain a linear relationship with the applied voltage, a non-sinusoidal current is formed, meaning harmonics are generated in the circuit. Harmonic frequencies are integer multiples of the fundamental frequency. As proven by the French math...
read more
-
May 25,2026
1. Introduction Three-phase unbalance is a prevalent power quality issue in low-voltage distribution systems, mainly caused by dispersed single-phase loads, charging piles and residential electricity consumption. Two mainstream solutions are widely used in the industry: mechanical relay phase-switching balancers and IGBT-based active compensation devices (SVG/APF/Active Load Balancer). This articl...
read more