-
Apr 17,2026
Low Voltage APF Active Power Filter APF Active Power Filter APF stands for Active Power Filter.Also known as Active Harmonic Filter.What is filtering?To put it simply: tap water in rivers contains all kinds of pollutants, and we install a water purifier at home to filter out impurities. Similarly, the current in the power grid is just like river water. APF filters out interference (impurities) in ...
read more
-
Apr 20,2026
Many novice electricians make mistakes when connecting frequency converters, sometimes resulting in inverter errors or even module failure, smoke, and fire. The problem isn't the wiring itself, but rather a lack of understanding of the core principles, especially the common mistake of reversing the input and output wires! This article breaks down the practical wiring methods for frequency converte...
read more
-
Apr 21,2026
Cycloconverters – the direct AC-to-AC power conversion circuits – hold a special place in high-power, low-speed applications like rotary kilns, mine hoists, and ship propulsion systems. Unlike conventional rectifier-inverter combinations, cycloconverters adjust output frequency without an intermediate DC link. However, this direct conversion comes at a cost: complex power factor behavior and prono...
read more
-
Apr 29,2026
When frequency inverters (especially PWM type) are operating, they generate a large number of harmonics due to the nonlinear characteristics of the rectification and inversion stages, which can interfere with the power grid and surrounding equipment. The following is a systematic explanation from three aspects: causes, hazards, and suppression methods. 1.Causes of harmonic interference The main ci...
read more
-
May 06,2026
With the development of industrial automation technology, frequency converters are being used more and more widely. Their excellent speed regulation performance and obvious energy-saving effect are increasingly praised. However, the harmonics generated by frequency converters during operation are causing more and more serious damage to the power grid. Therefore, the requirements for suppres...
read more
-
May 08,2026
1.What is Harmonics? In power systems, the fundamental cause of harmonics is the presence of non-linear loads. When current flows through a load and does not maintain a linear relationship with the applied voltage, a non-sinusoidal current is formed, meaning harmonics are generated in the circuit. Harmonic frequencies are integer multiples of the fundamental frequency. As proven by the French math...
read more