-
Nov 14,2022
With the continuous development of the market, we have more and more customers in the Middle East market using our APF(Active Power Filter) equipment. Active Power Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD-APF active power filter is connected in parallel, to detect th...
read more
-
Mar 17,2023
ZDDQ Active Power Filter Exported to Lebanon. We are ZDDQ, which is a professional designer and top manufacturer of power quality field. And we focus on power quality improvement and power factor correction since 2001. In recent years, our business sector in the Middle East has gradually expanded, and more and more customers choose to use ZDDQ products. The following is a 100A active harmonic filt...
read more
-
Aug 23,2023
ZDDQ----Power Quality Issues in the Data Center Industry A large number of modern electrical equipment and devices are used in the data center industry, such as credit card terminal equipment, communication systems, computers, network control equipment, various digital office equipment, lighting control systems, fire protection systems, monitoring systems, etc. A large number of non-linear power l...
read more
-
Mar 20,2024
Urban rail transit systems mainly include: subway systems, light rail systems, monorail systems, trams, maglev systems, automatic guide rail systems, and urban rapid rail systems. According to the different nature of electricity consumption, the power supply system of the subway system is mainly divided into two, one is the traction power supply system and the other is the power lighting power sup...
read more
-
May 06,2024
What is nonlinear load? A nonlinear load is a load whose current is not proportional to its voltage. Since some electronic components, such as transistors and diodes, exhibit nonlinear characteristics when operating, in actual power consumption, some electrical equipment connected to the load will deform the current waveform. This deformation causes the voltage to distort and generate additional f...
read more
-
Aug 27,2024
Harmonic voltage and harmonic current are common phenomena in power systems, and they have a great impact on power equipment and power grid operation. Harmonics refer to voltage or current components whose frequencies are integer multiples of the fundamental frequency. In power systems, the fundamental frequency is generally 50Hz or 60Hz, so the harmonic frequency is an integer multiple of 50Hz or...
read more
-
Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...
read more
-
Dec 17,2024
With the continuous advancement of science and technology, medical technology has been significantly improved, and advanced medical equipment continues to emerge, greatly improving the quality of medical services. However, the use of nonlinear devices in hospital power distribution systems may produce harmonic currents that can interfere with the normal operation of the system. The accumulation of...
read more
-
May 08,2025
1. Overview of the development of the power quality optimization and management equipment industry Power quality refers to the nature and characteristics of the power provided to users by the power supply system, including voltage fluctuations, frequency stability, harmonic content, voltage flicker, power interruption and other aspects. Good power quality is the basis for ensuring the normal opera...
read more
-
Aug 19,2025
In the marine industry, active filters are primarily used to address harmonics, improve power quality, and ensure stable operation of shipboard power systems. Specific applications are as follows: 1. Suppressing Harmonics in Radar Systems: Shipborne radar equipment has large capacity and experiences significant load fluctuations during operation, generating significant harmonics. Total harmonic di...
read more
-
Aug 19,2025
When multiple modules of an active power filter are operated in parallel, slow response and reduced filtering effectiveness are often related to imbalances in core aspects such as inter-module coordinated control, signal synchronization, and current distribution. The specific causes can be analyzed from the following aspects: Ⅰ. Insufficient inter-module synchronization accuracy Multiple modules i...
read more
-
Sep 10,2025
1. Electrical Resonance What is Resonance? In an AC circuit, electrical resonance is a condition where the inductive reactance (X_C) become equal, canceling each other out. This leaves only the circuit resistance (X_L = 2πfL): Opposition from inductors (e.g., motors, transformers). Increases with frequency. Capacitive Reactance (f_r) This is the specific frequency where f_r = 1 / (2π√(LC)) Wh...
read more
-
Oct 30,2025
Active Harmonic Filter is a high-power, fast-switching electronic amplifier. Its job is to continuously monitor the electrical system and instantly inject equal but opposite "anti-harmonic" currents to cancel out the distortions. This demanding process generates a significant amount of waste heat, and managing this heat is paramount for several key reasons: 1. To Protect the Power Semiconductors (...
read more
-
Dec 10,2025
The Variable Frequency Drive (VFD) is a powerhouse of modern industry, enabling precise motor control and dramatic energy savings. Yet, this efficiency comes with a hidden electrical toll: harmonic distortion. The Active Harmonic Filter (AHF) is the critical solution that neutralizes this threat, ensuring system reliability and clean power. The Harmonic Challenge from VFDs A VFD's operation—conver...
read more
-
Feb 07,2026
Below is a partial list of our shipments over the past two weeks at the end of the year: 1. Africa High Voltage Outdoor Water Cooling Statcom FAT and Delivery 2. Eastern European Static Var Generator and Active Harmonic Filter 3. Southeast Asia LV APFC 4. Latin American MV APFC(13.8kV)
read more