Jan 19,2024
Power Factor Control refers to the management and maintenance of an acceptable power factor in electrical systems. Power factor is the ratio of real power (kW) to apparent power (kVA) in an electrical circuit. A low power factor indicates that the circuit is inefficient and requires more current to deliver a given amount of power. This results in increased energy losses, higher electricity bills, ...
read more
-
Jan 29,2024
To build a capacitor bank panel, you will need to follow these general steps: Determine the capacitor bank size: Calculate the required capacitance based on the power factor correction needs of your system. Consider factors such as the target power factor, load characteristics, and voltage levels. Select capacitors: Choose high-quality capacitors that are suitable for the desired voltage and curre...
read more
-
May 13,2024
The improvement of power quality is mainly through power quality equipment and current signal and other parameters in the current transformer detection system, so as to correctly control the power quality problem in real time and improve the environment of the distribution system. For capacitor bank, we usually only use a CT mounted on the power side for sampling. For SVG / APF, a...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Sep 05,2024
Application of reactive power compensation device SVG: Power system: SVG can be used for reactive power compensation and voltage regulation of power system to improve the stability and reliability of power grid. It can help power system reduce power loss, improve voltage quality, and improve power factor and efficiency of power grid. Industrial field: SVG can be used for reactive power compensatio...
read more
-
Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...
read more
-
Oct 14,2024
Low-voltage capacitor cabinets are electrical equipment used in power systems. Their main function is to compensate the power factor of the power system and improve the power supply quality of the system. When installing low-voltage capacitor cabinets, the following aspects need to be noted: Installation location selection: Low-voltage capacitor cabinets should be installed in ventilated, dry, non...
read more
-
Oct 27,2024
Active Load Balancer and Active Power Filter Active Load Balancers and Active Power Filters (APFs) are both power quality devices, yet they serve different roles within electrical networks. Here’s an overview of each, along with their similarities and distinctions: Active Load Balancer Function: Primarily used to ensure balanced loading across all three phases in a power system. Operation: Activel...
read more
-
Dec 25,2024
Power quality analysis and improvement measures for cement plants The size of system voltage deviation, the degree of three-phase voltage imbalance, and the reliability of power supply have an important impact on the safe operation and service life of electrical equipment, and are also directly related to the safety, stability and economic operation of the cement plant power system itself. 1. Powe...
read more
-
May 22,2025
The low power factor of a single-phase circuit will lead to a decrease in equipment efficiency and an increase in line loss. To control the power factor, we need to analyze the causes and take targeted measures. The following are common control methods: I. Common causes of low power factor 1. Mainly inductive loads Equipment such as fluorescent lamps, motors, transformers, etc., need to consume re...
read more
-
Aug 19,2025
When multiple modules of an active power filter are operated in parallel, slow response and reduced filtering effectiveness are often related to imbalances in core aspects such as inter-module coordinated control, signal synchronization, and current distribution. The specific causes can be analyzed from the following aspects: Ⅰ. Insufficient inter-module synchronization accuracy Multiple modules i...
read more
-
Sep 10,2025
1. Electrical Resonance What is Resonance? In an AC circuit, electrical resonance is a condition where the inductive reactance (X_C) become equal, canceling each other out. This leaves only the circuit resistance (X_L = 2πfL): Opposition from inductors (e.g., motors, transformers). Increases with frequency. Capacitive Reactance (f_r) This is the specific frequency where f_r = 1 / (2π√(LC)) Wh...
read more
-
Oct 30,2025
Active Harmonic Filter is a high-power, fast-switching electronic amplifier. Its job is to continuously monitor the electrical system and instantly inject equal but opposite "anti-harmonic" currents to cancel out the distortions. This demanding process generates a significant amount of waste heat, and managing this heat is paramount for several key reasons: 1. To Protect the Power Semiconductors (...
read more
-
Dec 09,2025
The correct selection of capacitor banks, SVG (Static Var Generator), and active power filters (APF) and external current transformers (CTs) directly affects the measurement accuracy, response speed, and overall operational performance of the compensation/filtering device. The following details how to correctly select these components, covering both general principles and specific considerations f...
read more
-
Dec 10,2025
The Variable Frequency Drive (VFD) is a powerhouse of modern industry, enabling precise motor control and dramatic energy savings. Yet, this efficiency comes with a hidden electrical toll: harmonic distortion. The Active Harmonic Filter (AHF) is the critical solution that neutralizes this threat, ensuring system reliability and clean power. The Harmonic Challenge from VFDs A VFD's operation—conver...
read more
-
Feb 07,2026
Below is a partial list of our shipments over the past two weeks at the end of the year: 1. Africa High Voltage Outdoor Water Cooling Statcom FAT and Delivery 2. Eastern European Static Var Generator and Active Harmonic Filter 3. Southeast Asia LV APFC 4. Latin American MV APFC(13.8kV)
read more
-
Apr 01,2026
Product Uses: Intelligent reactive power compensation capacitor banks are "energy-saving experts" in power systems. Their main functions are: Compensating for reactive power losses in the power grid, improving the power factor, and avoiding power factor penalties for the power sector; (B) Reducing line losses and improving the power supply efficiency of the power grid; Stabilizing the power grid v...
read more