Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
Apr 24,2020
Following are simple contrast list, Product Static Var Generator(SVG) Multifunctional electricity controller & optimizer (MEC) Mechanical switch capacitor (MSC) Thyristor-switched capacitor (TSC) Response speed ≤5ms ≤5ms 300ms 20ms Reactive power compensation ability Rated capacitive reactive power to rated inductive reactive power, 0.1kVar precision, and up to 1 power factor Rated capacitive ...
read more
-
Apr 29,2020
STATCOM A static synchronous compensator, known as a STATCOM, is another device used to regulate the power factor in medium to high voltage applications. They operate on roughly the same principles as a synchronous compensator, however, use a voltage source converter as opposed to a rotating machine to provide dynamic Power Factor Correction. STATCOMs use IGBT switching te...
read more
-
May 06,2020
ZDDQ 690V Static Var Generator ZD-SVGM-2000 Static Var Generator (SVG) is the new standard in reactive energy compensation for 690V networks. This power electronic current source is the accurate and highly reliable solution for today’s networks characterised by significant increase in harmonics, voltage variations caused by intermittent renewable sources connected to the network and voltage level ...
read more
-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
May 26,2020
Power Factor: Power factor correction(Cosφ) Benefits of power factor correction Improves system power factor Reduces network losses Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availab...
read more
-
Jun 06,2020
Overview A New Generation in Power Factor Correction Today's automation equipment benefits us with greater convenience as well as cost savings from higher production efficiency. However, it can also bring significant wave distortion problems to the power grid that can lead to energy loss, increasing costs and many other power quality issues. A clean and efficient power system normally generates a ...
read more
-
Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Oct 21,2020
Our Indian Clients and African Clients has installed hybrid reactive power compensation system. After our guide, they use ZDDQ SVG mixed with Capapacitor banks based on Contactors and Thyristors. A united system of thyristor switched capacitor (TSC) and static var generator (SVG) was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Th...
read more
-
Oct 30,2020
Our low voltage Static Var Generator has widely installed in many countries and has a good function and quality performance. In some countries, client use our SVG to compensate reactive power together with their capacitor banks, which is named as hybrid compensation system. In some countries, our SVG are used for power factor correction at the site where the load changes fast and frequently. And s...
read more
-
Nov 23,2020
ZDDQ Static Var Generator SVG and Active Power Filter APF adopt dual interface of Current Transformer,which has great to facilitate new project design and adaptation to old projects. Our SVG and APF can accurately calculate the load harmonic current data and provide perfect compensation effect. For following sites, Both single module or multiple modules in parallel, Multiple active filter/SVGcabin...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Jan 05,2021
Research A recent ZDDQ survey shows that the global static VAR generator market is projected to grow remarkably owing to the persistent demand for stable power supply from the consumers. Knowing from Fortune Business Insights, in an upcoming report, titled, “Static VAR Generator“ Market Size, Share & Industry Analysis, By Type (Thyristor Based, MCR Based), By End-User (Electric Utility, Renewa...
read more
-
Jan 16,2021
Status analysis According to marketing research by ZDDQ(ANHUI ZHONGDIAN ELECTRC CO., LTD.). To reduce energy consumption and increase energy efficiency, many facility management executives are looking to renewable energy sources, such as solar or wind, to offset reliance on traditional electric power. Despite the growing prevalence of these solutions, there are drawbacks that can make alternative ...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more
-
Feb 18,2021
To all clients and friends, 2021 is Chinese Niu Year and Happy Chinese New Year. Best wishes to all our friends and clients from all over the world. Happy new year 2021 wishes for friends families. Warmest thoughts and best wishes for a Happy New Year. May peace, love, and prosperity follow you always. We have resume work On Feb 18th. Going on supporting power quality solutions Low voltage capacit...
read more