Jan 19,2024
Power Factor Control refers to the management and maintenance of an acceptable power factor in electrical systems. Power factor is the ratio of real power (kW) to apparent power (kVA) in an electrical circuit. A low power factor indicates that the circuit is inefficient and requires more current to deliver a given amount of power. This results in increased energy losses, higher electricity bills, ...
read more
-
Jan 29,2024
To build a capacitor bank panel, you will need to follow these general steps: Determine the capacitor bank size: Calculate the required capacitance based on the power factor correction needs of your system. Consider factors such as the target power factor, load characteristics, and voltage levels. Select capacitors: Choose high-quality capacitors that are suitable for the desired voltage and curre...
read more
-
Apr 12,2024
Zero sequence current, known as residual current or triplen harmonic current, is a phenomenon that occurs in electrical systems due to the presence of unbalanced loads or nonlinear loads. The primary reason for the presence of zero current is unbalanced loads. In a three-phase power system, the loads are ideally balanced, meaning that the three phases draw equal currents. However, in practical sce...
read more
-
May 13,2024
The improvement of power quality is mainly through power quality equipment and current signal and other parameters in the current transformer detection system, so as to correctly control the power quality problem in real time and improve the environment of the distribution system. For capacitor bank, we usually only use a CT mounted on the power side for sampling. For SVG / APF, a...
read more
-
May 30,2024
1. What are the 3rd, 5th, and 7th harmonics? In a normal power system, electrical equipment with linear impedance change characteristics will not affect the power supply with a frequency of 50Hz and a standard sinusoidal waveform when it is working. However, with the development of power electronics technology, there are more and more electrical equipment with nonlinear impedance characteristics (...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Jul 22,2024
Statcom, Current sampling and voltage sampling Current and Voltage Sampling in STATCOM Static Synchronous Compensator (STATCOM) is a device used for dynamic reactive power compensation and voltage stabilization in power systems. Accurate current and voltage sampling are crucial for the proper functioning of STATCOM, ensuring it provides the necessary reactive power compensation and voltage regulat...
read more
-
Aug 27,2024
Harmonic voltage and harmonic current are common phenomena in power systems, and they have a great impact on power equipment and power grid operation. Harmonics refer to voltage or current components whose frequencies are integer multiples of the fundamental frequency. In power systems, the fundamental frequency is generally 50Hz or 60Hz, so the harmonic frequency is an integer multiple of 50Hz or...
read more
-
Sep 11,2024
Selecting the capacity of the transformer is crucial, as it directly affects the stability, efficiency and safety of the power system. The appropriate transformer capacity can ensure that current and future load requirements are met, avoiding equipment damage and energy waste caused by overload or underload. The correct capacity selection helps optimize operating costs, extend equipment life, and ...
read more
-
Oct 14,2024
Low-voltage capacitor cabinets are electrical equipment used in power systems. Their main function is to compensate the power factor of the power system and improve the power supply quality of the system. When installing low-voltage capacitor cabinets, the following aspects need to be noted: Installation location selection: Low-voltage capacitor cabinets should be installed in ventilated, dry, non...
read more
-
Dec 25,2024
Power quality analysis and improvement measures for cement plants The size of system voltage deviation, the degree of three-phase voltage imbalance, and the reliability of power supply have an important impact on the safe operation and service life of electrical equipment, and are also directly related to the safety, stability and economic operation of the cement plant power system itself. 1. Powe...
read more
-
Mar 05,2025
Benefits of harmonic control Improve power quality: Harmonics can distort voltage and current waveforms. Controlling harmonics can make voltage and current waveforms closer to sine waves, provide stable and high-quality power for various electrical equipment, ensure normal operation of equipment, and reduce equipment failures and malfunctions caused by power quality problems. Reduce equipment loss...
read more
-
May 22,2025
The low power factor of a single-phase circuit will lead to a decrease in equipment efficiency and an increase in line loss. To control the power factor, we need to analyze the causes and take targeted measures. The following are common control methods: I. Common causes of low power factor 1. Mainly inductive loads Equipment such as fluorescent lamps, motors, transformers, etc., need to consume re...
read more
-
Dec 09,2025
The correct selection of capacitor banks, SVG (Static Var Generator), and active power filters (APF) and external current transformers (CTs) directly affects the measurement accuracy, response speed, and overall operational performance of the compensation/filtering device. The following details how to correctly select these components, covering both general principles and specific considerations f...
read more
-
Feb 07,2026
Below is a partial list of our shipments over the past two weeks at the end of the year: 1. Africa High Voltage Outdoor Water Cooling Statcom FAT and Delivery 2. Eastern European Static Var Generator and Active Harmonic Filter 3. Southeast Asia LV APFC 4. Latin American MV APFC(13.8kV)
read more
-
Apr 01,2026
Product Uses: Intelligent reactive power compensation capacitor banks are "energy-saving experts" in power systems. Their main functions are: Compensating for reactive power losses in the power grid, improving the power factor, and avoiding power factor penalties for the power sector; (B) Reducing line losses and improving the power supply efficiency of the power grid; Stabilizing the power grid v...
read more