Mar 11,2020
Product Description ZDDQ Medium Voltage Metal Enclosed Capacitor and Harmonic Filter Banks are designed for industrial, commercial, and utility power systems requiring medium voltage automatic power factor correction. Standard designs are available for placement in outdoor or indoor substations (an enclosure integrity option can be added to allow for placement in publicly accessible areas) for pow...
read more
-
Mar 17,2020
China's economy According to China Daily China's economy is gradually returning back to normal, as major industrial companies outside of Hubei province have resumed work at a rate of more than 90 percent, China's top economic regulator said on Tuesday. The nonferrous metal industry's electricity consumption has reached normal level last year, and power consumption in the medical, chemical and elec...
read more
-
Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Mar 28,2020
Power quality “Power quality” can seem to be a pretty abstract term – how does one judge the quality of such an unseen commodity as electricity? But, as commercial and industrial facility managers know, good power quality can boost both productivity and employee safety, while poor power quality can mean a drain on the bottom line, thanks to damaged equipment, lost productivity and product spoilage...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
Apr 18,2020
Power quality problems and Industry background Dynamic reactive power, lower power factors, and higher harmonic content are common power quality problems in the CNC industry. Major contamination sources of power quality include the punching machines,welding machines. When harmonics occur, dynamic reactive current and 3-phase imbalance are produced. During the CNC period, the power factor of arc fu...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 08,2020
How to calculate Harmonic Filter In power supply systems based on alternating current (AC) -- such as the main power distribution network from electric utilities -- non-linear loads can feed some amount of power back into the wiring. This feedback typically occurs in the form of harmonics: multiples of the frequency of the original AC wave. Harmonics need to be eliminated from a power circuit by a...
read more
-
Aug 03,2020
Low Power Factor Operation of Induction Motor Induction Motors finds various applications in industries and household equipments. Such machine requires magnetic fields for its functioning hence, it draws magnetizing current from the source. The magnetizing current is the current that establishes the flux in the air gap of an Induction motor and this is independent of the load on the motor. It is t...
read more
-
Sep 24,2020
480V power quality solutions has the best compatibility for low voltage grid(3 phase 4 wire).ZDDQ has full series 480V devices for power quality improvement and power factor correction. 480V Active Power Filter Active Power Filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensa...
read more
-
Oct 21,2020
Our Indian Clients and African Clients has installed hybrid reactive power compensation system. After our guide, they use ZDDQ SVG mixed with Capapacitor banks based on Contactors and Thyristors. A united system of thyristor switched capacitor (TSC) and static var generator (SVG) was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Th...
read more
-
Nov 11,2020
With our best quality of our products and good relationship in the power quality field, we just received an important order for medium voltage capacitor banks. Backgroud. The rated voltage is 10kv. The total capacity is 35.4Mvar. There are individual type capacitor banks, central capacitor banks. Also there are fixed capacitor banks, and mulitipl-step automatic capacitor banks. As we know, STATCOM...
read more
-
Nov 23,2020
ZDDQ Static Var Generator SVG and Active Power Filter APF adopt dual interface of Current Transformer,which has great to facilitate new project design and adaptation to old projects. Our SVG and APF can accurately calculate the load harmonic current data and provide perfect compensation effect. For following sites, Both single module or multiple modules in parallel, Multiple active filter/SVGcabin...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Dec 18,2020
Introduction From ZDDQ professional engineers: Power systems are designed to operate at frequencies of 50 or 60Hz. However, certain types of loads produce currents and voltages with frequencies that are integer multiples of the 50 or 60 Hz fundamental frequency. These higher frequencies are a form of electrical pollution known as power system harmonics. Solution ZD-APF(Active Power Filter). This i...
read more
-
Dec 26,2020
Power factor is the percentage of consumed power(KW) versus supplied power(KVA). This is important because a low power factor can waste energy, result in inefficient use of electrical power, and often result in higher energy bills. Power Factor Correction will improve the energy efficiency of any electrical system, but a reduction in your power bill is only available where a power company charges ...
read more
-
Jan 05,2021
Power factor correction capacitor banks and harmonic filters. Power factor correction capacitors and harmonic filters are an essential part of modern electric power systems. Power factor correction capacitors are the simplest and most economical means of increasing the capacity of any power system, minimizing energy losses and correcting load power factor. In addition, power factor penalties can b...
read more
-
Jan 21,2021
ZDDQ Engineers give an example for reference, An Alternator is supplying a load of 650 kW at Power factor 0.65. What size of Capacitor banks (kVAR) is required to raise the Power Factor to unity (1 or >0.95)? And how many more kW can the alternator supply for the same kVA loading when P.F improved. Supplying kW = 650 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = Cos-1 = (0.65) = 49°...
read more