ZDDQ hybrid dynamic reactive compensation device adopts the configuration scheme of combining static var generator and switching capacitor/reactor, and implements different reactive compensation schemes according to the actual needs of users on site, so as to achieve the best combination of price and effect.
Brand:
ZDDQitem no.:
ZD-HYB-SASPayment:
LC,TTproduct origin:
ChinaColor:
RAL7035shipping port:
ShanghaiLead Time:
15daysOverview
ZD-CSVG-2000 hybrid dynamic reactive compensation device consists of two parts – static reactive generator unit and switching capacitor / reactor reactive compensation unit. In ZD-CSVG-2000 hybrid dynamic reactive compensation device, each unit is designed and produced in the method of low power, small volume and low cost, and both of them are optional, and can be combined in the best and flexible way according to the actual reactive state of the site, so as to achieve the optimum ratio of operation effect and cost.
Typical Design
The reactive compensation is usually configured on the basis of 30% of the transformer capacity, for example, 400KVA transformer is usually configured with 120kvar-capacity reactive compensation device, and in special cases, first test the power quality, and then confirm the configuration capacity according to the test result.
SVG module and capacitor capacity in the compensation capacity can be configured flexibly, to achieve the optimum compensation effect.
Hybrid PFC
|
Technical Data
Electrical properties
Rated voltage
400/690VAC
Operating frequency
50/60Hz
Electrical connection
Three-phase four-wire/ three-phase three-wire
Capacity of whole cabinet
50~500kvar
Switch of capacitors
Thyristor,compound switch, contactors
Compensation mode
Either three-phase compensation or single-phase compensation
Compensation effect
The system power factor is greater than 0.98 after compensation within the rated capacity.
SVG module response time
<5ms
Capacitor response time
<1s
Active loss of system
<3%
Output current limit
Automatically limited within 100% of rated capacity to output
Number of units connected in parallel
≤10 units
MTBT
>100,000 hours
Control characteristics
Controller
DSP+FPGA
Switching frequency
12.8K
Capacitor control interface
16 ways
Communication mode
Adopt Modbus remote communication protocol; communication interface adopts RS485 and CAN bus, supporting USB data download.
Control connection
Fiber or electrical connection
Structural characteristics
Weight
Refer to the model selection table.
Level of protection
IP20
Cooling method
Air cooling
Noise
<50db
Installation method
Cabinet mounting.
Environmental requirements
Ambient temperature
-20~55℃
Relative humidity
Maximum 95%, without condensation
Mounting height above sea level
≤1,000m at rated capacity; appropriately reduce the capacity if it is greater than 1,000m
Typical Applications
SVGs have many low and high voltage potential applications where their use offers many benefits.
Responding to System Variations
The increase of non-linear and other challenging loads in electrical grids present unique power quality challenges. As a result ZDDQ has developed a ZD-CSVG-2000 hybrid dynamic reactive compensation device that provides a cost effective and very fast solution to power system variations enabling longer equipment life, higher process reliability and reduced energy losses, complying with most demanding power quality standards and grid codes.
ZD-CSVG-2000 hybrid dynamic reactive compensation device is a flexible, high performance and cost effective solution used to mitigate power quality problems generated by the equipment installed in electric power systems, enhancing equipment operating life-time, and improving power system capacity. These Smart Active Power Quality hybrid systems can be programmed to provide the following functions in real time:
Hybrid dynamic reactive compensation
ZD-CSVG-2000 hybrid dynamic reactive compensation device has many competitive Advantages:
Model Table
Applied Type | Model | Voltage Class | SVGM Module Capacity | Capacitance | Dimension |
SVG Module | ZD-CSVG-2000/50 | 400V | 50kvar | 0kvar | 800×600×1,200mm |
ZD-CSVG-2000/100 | 400V | 50kvar | 50kvar | 800×600×1,200mm | |
ZD-CSVG-2000/240 | 400V | 50kvar | 190kvar | 800×600×1,200mm | |
ZD-CSVG-2000/360 | 400V | 50kvar | 310kvar | 800×600×1,200mm | |
Higher capacity | 400V | Customized | Customized | Standard cabinet/ Customized |
Applications
ZD-CSVG-2000 hybrid dynamic reactive compensation device are widely used for fluctuating loads such as motors, variable frequency drives, melting furnace from Steel Rolling mills,Chemical industry,Cement plant, Suger plant, Textile, Hospitals, Hotels, Building segment,Automobile industry,Oil and gas industry, public grid etc.
Scan to WhatsApp: