Mar 11,2021
Basic Datas of Harmonics and VFD Harmonic Distortion Harmonic Distortin is a measure of the amount of deviation from a pure sinusoidal wave form that can be caused by a non-linear load (a VFD is considered a non-linear load because it only draws current from the power line as required). Distorted Waveform Distorted Waveform = fundamental (50Hz sinusoidal waveform) + multiples of the fundamental fr...
read more
-
Mar 19,2021
Problems of Line Side Harmonics The two main line side harmonic concerns are the problems caused in the facility where they are being generated and the degree of harmonic infection passed to neighboring facilities. The degree of impact for either area depends on the number, size and frequency of use of all linear and non-linear loads . Mainly introduce harmoncs within a facility here. Within a fac...
read more
-
Mar 30,2021
Why harmonics analysis? When a voltage and/or current waveform is distorted, it causes abnormal operating conditions in a power system such as: Voltage Harmonics can cause additional heating in induction and synchronous motors and generators. Voltage Harmonics with high peak values can weaken insulation in cables, windings, and capacitors. Voltage Harmonics can cause malfunction of different elect...
read more
-
Jun 07,2021
Energy consumption pattern The energy pattern given in below table is helpful in understanding the way energy is used in a foundry and helps to control energy cost by identifying areas where waste can occur and where scope for improvement may be possible. It is observed that melting consumes a major portion of total energy consumed. SN Sections Energy Consumption 1 Melting(Furnance) 70% 2 Molding ...
read more
-
Dec 04,2021
ZDDQ Active Harmonic Filter Active harmonic filter is connected in parallel with non-linear loads, and uses one set of CT to detect the load current. It calculates each order harmonic current by FFT algorithms in its DSP microchips, and then generates a compensating current with the same amplitude but opposite phase angles to the detected harmonic current, which cancels out the original load harmo...
read more
-
Mar 09,2022
Thanks for our friend from Korea. 300A Active Power Filter have been shipped to Korea. Welcome to talk with us for any power quality project, ZDDQ provide efficient, reliable, competitive power quality products, such as Active Harmonic Filter, Static Var Generator, Capacitor Bank and Statcom
read more
-
Apr 15,2022
Thanks for professional job from our clients' team and our technical team. This is our first AHF device installed in Korea and have so perfect technical performance. Welcome to view our AHF,SVG,Statcom product.
read more
-
Apr 20,2022
Active Harmonic Filter in Food Industry(Pakistan) Our client of Food Factory is a famous and one of the biggest factory in Pakistan. Thanks for Mr Abudal's professional job. And the AHF have achieve a good effect till now. We have finished the installation and commissioning the Active Harmonic Filter at site. The THDI has reduced to 3% from 60%.
read more
-
May 10,2022
CE is approved by Italy Lab. Active Power Filter Active Harmonic Filter Static Var Generator
read more
-
Jul 05,2022
Step–less reactive compensator –STATCOM Static Synchronous Compensator (STATCOM) hasearned its name as it does not have any rotating or moving parts, and yet offers a fast and step-less reactive compensation. It is based on voltage source converter (VSC) technology, which uses low-voltagecells in series to realise a high voltage output By controlling the output voltage to be either higher or lower...
read more
-
Aug 03,2022
Energy demand is anticipated to be double by 2030. CO2 emissions should be halved to avoid global warming acceleration. Both issues place a major challenge on the generating capacity of all utilities, and on us as electricity end users. Energy efficiency becomes more than a cost issue today. It becomes part of the journey to ensure energy availability and preserve the environment in the future. Ma...
read more
-
Nov 14,2022
With the continuous development of the market, we have more and more customers in the Middle East market using our APF(Active Power Filter) equipment. Active Power Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD-APF active power filter is connected in parallel, to detect th...
read more
-
Jan 11,2024
STATCOM (Static Synchronous Compensator) is a power electronic device used in electrical power systems for voltage control and power factor correction. In a solar farm, the main functions of a STATCOM are as follows: Voltage Regulation: Solar farms typically operate at high voltages, and fluctuations in solar irradiation and load demand can cause voltage variations. STATCOMs can regulate the volta...
read more
-
Jan 22,2024
n the context of the metallurgical industry, Statcom refers to Static Var Generator(SVG) or Static synchronous Compensator, which is a type of power electronics-based device used for reactive power compensation and voltage control. Statcoms are commonly used in metallurgical processes to improve power quality and stabilize the voltage levels. The primary function of an Statcom in the metallurgical...
read more
-
Feb 19,2024
What is harmonics issues in AC and DC grid? In AC and DC grids, harmonics refer to the presence of frequency components that are integer multiples of the fundamental frequency. Harmonics can be problematic because they can cause various issues such as: Voltage and Current Distortion: Harmonics in the grid can distort the shape of the voltage and current waveforms, resulting in distorted sine waves...
read more
-
Mar 25,2024
Static Synchronous Compensator (STATCOM) is a device used in power systems to control voltage and reactive power. In the context of rail transit, STATCOM can serve several purposes: Voltage Regulation: STATCOM can regulate the voltage levels in the rail transit system, ensuring that they remain within acceptable limits. It can compensate for voltage drops or fluctuations caused by various factors ...
read more
-
May 13,2024
The improvement of power quality is mainly through power quality equipment and current signal and other parameters in the current transformer detection system, so as to correctly control the power quality problem in real time and improve the environment of the distribution system. For capacitor bank, we usually only use a CT mounted on the power side for sampling. For SVG / APF, a...
read more
-
Jul 01,2024
STATCOM (Static Synchronous Compensator) is a power electronic device used power systems for voltage control and power factor correction. While Statcom are not directly related to coal mining operations, they can play a role in providing stable and reliable electrical power for mining operations, including coal mines. Coal mines typically require a significant amount of electrical power for variou...
read more